
This VILVA 200kW 450A DC resistive load bank provides harmonic-free discharge testing for energy storage packs, UPS and DC power supplies. Featuring stepped load control, multi-safety protection and forced air cooling, it supports reliable unattended capacity verification. Optional data logging captures test data and exports curves for official acceptance.
Pain Points & Solutions
❌Electronic active loads introduce harmonic distortion, failing to satisfy strict site acceptance specifications for power systems and battery banks.
✅It adopts pure resistive loading topology with linear, distortion-free loading characteristics, fully complying with field acceptance criteria.
❌Extended discharge validation requires continuous operation, yet inadequate protection raises risks of thermal runaway and equipment damage.
✅Integrated multi-layer protection including overtemperature, overcurrent, undervoltage cutoff and emergency halt enables reliable unattended long-duration discharge validation.
❌Project handover and third-party audits require traceable test records, capacity curves and formal test documentation.
✅Optional high-precision data acquisition module logs real-time voltage, current and cumulative capacity; test data and curves can be exported via USB for official reports.
❌Fixed loading modes cannot match variable rated parameters of different battery modules, UPS and DC power assets.
✅Stepwise load switching design allows segmented adjustment of discharge current to adapt to diverse test objects and validation requirements.
❌High-power continuous testing often suffers from insufficient heat dissipation, leading to derating and unstable test results.
✅Optimized forced-air cooling system sustains full-load continuous operation, avoiding power derating and guaranteeing repeatable, consistent test data.
Application Fields
Offline capacity validation and ageing characterization for energy storage battery packs
Acceptance testing and commissioning of DC power supplies and rectifier cabinets
Periodic capacity inspection and preventive maintenance for telecom backup battery banks
Performance verification of battery strings for UPS and substation power systems
Bench test and witness calibration services at third-party electrical test laboratories
Discharge validation for marine DC power systems and data center backup power assets
Click Here to Start Contacting Us
Hot Questions(RFQ):
Q1: Does it produce harmonics during discharge testing?
A1: No. It adopts pure resistive load without harmonic distortion.
Q2: Can it record test data and export curves for acceptance?
A2: Yes. An optional data logger captures real-time voltage, current and capacity, exportable via USB.
Q3: Is the load adjustable?
A3: Yes, it supports step-by-step load adjustment for different high-current test requirements.
Q4: Can it run unattended long-duration discharge tests?
A4: Yes. Efficient forced air cooling and multi-protection system support continuous unattended testing.
Q5: What safety protections are equipped?
A5: Over-temperature protection, overcurrent protection, under-voltage protection and emergency stop function.
Q6: Can this machine be customized?
A6: Yes, we support customization of DC voltage range, terminals and special functions.
Q7: What is the cooling type?
A7: Forced air cooling, stable heat dissipation for continuous high-current discharge.
Q8: Is it suitable for on-site commissioning or only lab use?
A8: It supports both factory laboratory testing and field on-site commissioning.
Q9: What kind of batteries or power systems can it test?
A9: Energy storage packs, telecom battery banks, UPS and DC power supply systems.
Q10: Do you provide calibration certificates?
A10: Yes, calibration certificates are available upon request at extra cost.
Q11: What is the lead time after order confirmation?
A11: Normally 15–25 working days, subject to configuration and quantity.
Q12: Can we connect multiple units in parallel for higher current?
A12: Yes, parallel operation is available as a customized solution.



















